Cut to Length with Multi Stroke Program
Fault signal on Pac-Sci Servo fault Recycle
power
is displayed Material jam Check cutter
Power surge/failure
Check/recycle power
Cannot program unit Program fault Check Pac-Sci &
Call
factory.
Mechanical pilot release Too much overtravel Restrict travel of
sticks down mechanical
actuating
arm
Broken spring Remove
plate and check
springs
Needs lube Remove
plate
and
lubricate release bar