13
Problem Possible Causes Remedy
characteristics and possible causes
of troubles with rapid-air feeds (continued)
Slide block will move out okay,
but will not return without
hesitation.
Feed acts sluggish on start up.
Okay after running for awhile.
Check speed adjusting screw.
Check pilot operated valve.
Swollen “O” ring could be binding,
until pressure build up breaks it free.
Check poppet valve.
Check pilot operated valve for
“O” rings binding. Valve should
move freely in cartridge.
Adjust for smooth operation.
Check moisture content in air lines.
Change “O” rings.
This usually occurs after a period
of non-running. After running unit for
awhile the unit usually frees up okay.